ID 110618
For the 'probing_command_start' signal was a invalid bit number configured. | ||||
Description | When configuring the SERCOS realtime control bits for the signal 'command start probing', an invalid bit number was entered either in P-AXIS-00700 . | |||
Response | Class | 3 | Output of an error message containing the axis parameters P-AXIS-00118 (measurement axis) and P-AXIS-00098 (kasto_achse) are reset, in order to prevent the execution of measurement run or edge bending with incompletely configured probes. | |
Solution | Class | 1 | P-AXIS-00700 must be corrected. | |
Parameter | %1: |
| ||
Log. Axis number | ||||
%2: |
| |||
Incorrect value of P-AXIS-00700 | ||||
%3: |
| |||
Permissible minimum value. | ||||
%4: |
| |||
Permissible maximum value. | ||||
Error type | 2, Error message by data transfer from parameter list into control device. | |||
|