ID 120025

Maximum difference of radii exceeded.

Description

When programming circles G02, G03, or it may occur also if generation of CNC code is done in CAD/CAM system, the calculated radius of circle start point and circle end point may vary. The resulting radius difference should not exceed maximum permissible radius difference limit. The error can occur quite often in conjunction with inactive circle centre point correction (G164).

For further information see [PROG// Controlling centre point offset ].

Response

Class

2

Program execution stop.

Solution

Class

6

Correction of programmed circle end point in CNC program.

Parameter

%1:

Error value [0.1 µm or 0,0001°]

Current radius difference of circle start point and circle end point.

%2:

Upper limit value [0.1 µm or 0,0001°]

Maximum permissible radius difference

%3:

Current value [0.1 µm or 0,0001°]

Circle start radius

%4:

Current value [0.1 µm or 0,0001°]

Circle end radius

Error type

1, Error message from NC program.