ID 120129
Corner deviation too small. | ||||
Description | In parameter setting of polynomial contouring ((#CONTOUR MODE[]), the programmed parameter for corner deviation (keyword PATH_DEV) is smaller than minimum permissible value. For further information see PROG//Section: Polynomial contouring]. | |||
Response | Class | 2 | Program execution stop. | |
Solution | Class | 6 | Corner deviation greater than minimum value in CNC command. | |
Parameter | %1: | Current value [0.1 µm or 0,0001°] | ||
Current programmed corner deviation. | ||||
%2: | Limit value [0.1 µm or 0.0001°] | |||
Minimum permissible corner deviation. | ||||
Error type | 1, Error message from NC program. | |||
|