ID 120129

Corner deviation too small.

Description

In parameter setting of polynomial contouring ((#CONTOUR MODE[]), the programmed parameter for corner deviation (keyword PATH_DEV) is smaller than minimum permissible value.

For further information see PROG//Section: Polynomial contouring].

Response

Class

2

Program execution stop.

Solution

Class

6

Corner deviation greater than minimum value in CNC command.

Parameter

%1:

Current value [0.1 µm or 0,0001°]

Current programmed corner deviation.

%2:

Limit value [0.1 µm or 0.0001°]

Minimum permissible corner deviation.

Error type

1, Error message from NC program.