ID 120131

Distance of corners too small.

Description

In parameter setting of polynomial contouring ((#CONTOUR MODE[]), the programmed parameter for corner distance (key words PRE_DIST, POS_DIST) is smaller than minimum permissible value.

For further information see [PROG// Section: Polynomial contouring].

Response

Class

2

Program execution stop.

Solution

Class

6

Corner distance greater than minimum value in CNC command.

Parameter

%1:

Current value [0.1 µm or 0,0001°]

Current active corner distance

%2:

Limit value [0.1 µm or 0.0001°]

Minimum permissible corner distance.

Error type

1, Error message from NC program.