ID 120204

Change of coordinate system with polynomial contouring active.

Description

If the smoothing function G61, G261 is active, the Cartesian transformation cannot be selected or deselected by the commands #CS ON[] or #CS OFF.

For more information on polynomial contouring see
[PROG// Section: Polynomial contouring].

Response

Class

2

Program execution stop.

Solution

Class

6

Before selecting or deselecting the Cartesian transformation, the polynomial contouring must be deactivated via G260.

Error type

1, Error message from NC program.