ID 120204
Change of coordinate system with polynomial contouring active. | |||
Description | If the smoothing function G61, G261 is active, the Cartesian transformation cannot be selected or deselected by the commands #CS ON[] or #CS OFF. For more information on polynomial contouring see | ||
Response | Class | 2 | Program execution stop. |
Solution | Class | 6 | Before selecting or deselecting the Cartesian transformation, the polynomial contouring must be deactivated via G260. |
Error type | 1, Error message from NC program. | ||
|