ID 120542

Parameter change during active b-spline interpolation not possible.

Description

An attempt was made to change the parameterization when B-spline path smoothing was active.
(e.g. #HSC [BSPLINE TRACK_DEV=5 MERGE=0 AUTO_OFF_PATH=1]).
Please turn off B-spline before parameters are changed.

Response

Class

1

The new value of the parameter is dismissed

Solution

Class

1

Change of NC-program

Parameter

%1:

NC block number [-]

Block number of parameter change

%2:

Current value [-]

Parameter type:

0x0040 PATH_DEV
0x0080 TRACK_DEV
0x0100 MAX_PATH_LENGTH
0x0200 MAX_ANGLE
0x0400 AUTO_OFF_G00
0x0800 MERGE_DEV
0x1000 MERGE_RETRY
0x2000 MERGE_WINDOW
0x4000 PATH_SPLIT bzw AUTO_OFF_PATH

0x8000 TRACK_SPLIT bzw AUTO_OFF_TRACK

0x10000 LIMIT_CORNER_DIST

%3:

Current value [-]

Current parameter value

%4:

Error value [-]

Wanted, new value of parameter

Error type

1, Error message from NC program.