ID 120652

Measurement during active polynomial contouring not possible.

Description

While polynomial contouring is active, it is impossible to execute a measurement run.

 

Example:

N010 G261

N020 G0 Z100

N030 G0 Z200 Y50

N040 G100 X100 F1000 (=> Error 120652)

N980 G260

N990 M30

Correct:

N010 G261

N020 G0 Z100

N030 G0 Z200 Y50

N050 G260

N040 G100 X100 F1000

N050 G261

N980 G260

N990 M30

Response

Class

2

Abort NC program.

Solution

Class

6

Correct NC program, deactivate polynomial contouring during measurement run

Parameter

%1:

NC block number [-]

Block number in which the error occurred.

%2:

Current value [-]

 

Error type

1, Error message from NC program.