ID 120671

Tube projection, programmed contour exceeds Y-limits with tube projection.

Description

With active tube processing, the contour has to be programmed inside the permissible limits in the projection plane. The symmetrical limit value is programmed in #CYL[] command, the default value is 0.25*radius of tube.

This case is a contour description which exceeds the permissible limits.

For further information on this function, see [FCT-M5// Round pipe and section tube machining].

Response

Class

2

Program execution stop.

Solution

Class

6

Keep programmed movement in the CNC program within the allowed range depending on limits, see below.

Parameter

%1:

Current value [0.1 10^-3 mm or ø]

Current Y- position from programmed contour.

%2:

Lower limit value [0.1 10^-3 mm or ø]

Permissible positive Y-value.

%3:

Upper limit value [0.1 10^-3 mm or ø]

Permissible negative Y-value.

Error type

1, Error message from NC program.