ID 120671

Tube projection, programmed contour exceeds Y limits.

Description

In tube processing, the contour must be programmed within the permissible limits in the projection plane. The symmetrical limit value is programmed in #CYL[] command; the default value is 0.25*radius of tube.

This case is a contour description which exceeds the permissible limits.

For further information on this function, see [FCT-M5// Tube processing].

Response

Class

2

Program abort.

Solution

Class

6

Keep programmed path motion in the CNC program within the allowed range depending on limits, see below.

Parameter

%1:

Current value [0.1 10^-3 mm or ø]

Current Y position of programmed contour.

%2:

Lower limit value [0.1 10^-3 mm or ø]

Permissible positive Y value.

%3:

Upper limit value [0.1 10^-3 mm or ø]

Permissible negative Y value.

Error type

1, Error message from NC program.