ID 150051

Invalid index of continuous jog velocity.

Description

CNC is in manual mode and in ENABLED state.

This message is issued because the CNC was commanded to adopt the motion velocity value in continuous jog mode (P-AXIS-00077) from the axis parameter data record. It is possible to parameterise several motion velocities in the axis parameter data record and therefore the value used is selected by a index.

When the CNC accepts the data, it detects that no entry exists in the axis parameter data record for the transferred index.

Response

Class

1

Warning

The active motion velocity for continuous jog mode at this time is maintained.

Solution

Class

1

Change the index to command the activation of continuous jog mode

or

Add an entry to the axis parameter data record for P-AXIS-00077 under the corresponding index.

Parameter

%1:

Current value [-]

Index of motion velocity for continuous jog mode for which no entry exists in the axis parameter data record.

Error type

-