ID 150088
Number of hand wheels does not coincide number of logical hand wheels. | ||||
Description | When interpreting manual mode parameter, it is detected that there are more or less handwheel parameter sets than determined by parameter P-MANU-00001 . | |||
Response | Class | 3 | Manual mode parameters aren’t taken over into CNC, but CNC start-up is continued using default parameters. | |
Solution | Class | 6 | Correct value for parameter P-MANU-00001 or Add missing/remove surplus handwheel parameter data sets. | |
Parameter | %1: | Current value [-] | ||
Value of parameter P-MANU-00001 from manual operation parameter data set. | ||||
%2: | Expected value [-] | |||
During interpretation of manual mode parameters, handwheel parameter sets were found. | ||||
Error type | 2, Error message by data transfer from parameter list into control device. | |||
|