ID 150088

Number of hand wheels does not coincide number of logical hand wheels.

Description

When interpreting manual mode parameter, it is detected that there are more or less handwheel parameter sets than determined by parameter P-MANU-00001 .

Response

Class

3

Manual mode parameters aren’t taken over into CNC, but CNC start-up is continued using default parameters.

Solution

Class

6

Correct value for parameter P-MANU-00001

or

Add missing/remove surplus handwheel parameter data sets.

Parameter

%1:

Current value [-]

Value of parameter P-MANU-00001 from manual operation parameter data set.

%2:

Expected value [-]

During interpretation of manual mode parameters, handwheel parameter sets were found.

Error type

2, Error message by data transfer from parameter list into control device.