ID 150089

Number of keys does not match the number of logical keys.

Description

When interpreting manual mode parameter, it is detected that there are fewer handwheel parameter sets than determined by parameter P-MANU-00008.

Response

Class

3

Manual mode parameters aren’t taken over into CNC, but CNC start-up is continued using default parameters.

Solution

Class

6

Correct value for parameter P-MANU-00008

or

Add missing key parameter data sets.

Parameter

%1:

Current value [-]

Value of parameter P-MANU-00008 from manual operation parameter data set.

%2:

Expected value [-]

Curing interpretation of manual mode parameters, key parameter sets were found.

Error type

2, Error message by data transfer from parameter list into control device.