ID 294506
KPS: Under voltage PMx. | |||
Description | The internal operating voltage (+15V) of the servo output stage is monitored. If the servo output stage is not ready, the intermediate circuit voltage may be too low. This occurs cyclically. | ||
Response | Class | 7 | Maximum braking. All active commands inhibited. |
Solution | Class | 6 | Eliminate error. Reset by pressing the hardware acknowledgement button ACK on the DSE I module. |
Error type | 11, Error message from position controller. | ||