ID 294560

KPS: Position tracker transmission error DSE - RDW.

Description

Damaged cable or plug connection between DSE and RDW, which are only used for position trackers.

Cable not connected or connected incorrectly.

Data transmission malfunction.

Response

Class

1

Output signal $POS_TRACKER_ERROR is set.

Solution

Class

1

Check DSE and RDW power supply (LEDs).

Check cable (screen!) and plug-in connections.

Check serial DSE - RDW interface.

Check grounding connection.

Error type

11, Error message from position controller.