Parameters

Cycle parameters

Description

@P4

Measurement path in the X axis (incremental)

Positive value, the touch probe moves in positive X direction

Negative value, the touch probe moves in negative X direction

@P6

Measurement path in the Z axis (incremental)

Positive value, the touch probe moves in positive Z direction

Negative value, the touch probe moves in negative Z direction

@P7 (optional)

Zero offset to be described (TCS)

G54 to G59

Input without address “G”

If not specified, then measurement only but no write function

@P9 (optional)

Shift the measuring point along the X axis

@P11 (optional)

Shift the measuring point along the Y axis

@P17 (optional)

Pre-position along the X axis

Default value = @P4

@P19 (optional)

Pre-position along the Z axis

Default value = @P6