Parameters
Cycle parameters | Description |
@P4 | Measurement path in the X axis (incremental) Positive value, the touch probe moves in positive X direction Negative value, the touch probe moves in negative X direction |
@P6 | Measurement path in the Z axis (incremental) Positive value, the touch probe moves in positive Z direction Negative value, the touch probe moves in negative Z direction |
@P7 (optional) | Zero offset to be described (TCS) G54 to G59 Input without address “G” If not specified, then measurement only but no write function |
@P9 (optional) | Shift the measuring point along the X axis |
@P11 (optional) | Shift the measuring point along the Y axis |
@P17 (optional) | Pre-position along the X axis Default value = @P4 |
@P19 (optional) | Pre-position along the Z axis Default value = @P6 |