Parameters
The touch probe must be configured in addition to supplying the input parameters described here. For more information on this function, see the section Configuration file.
The (calibrated) parameters of the touch probe (radius, length and offset in X and Y directions) are specified via the tool parameters.
Required input parameters
Input parameters | Description |
@P2 | Drilled hole diameter |
@P22 | Pre-position along the Z axis above the drilled holes |
@P29 | Hole circle diameter |
Optional input parameters
Input parameters | Description |
@P7 | Zero offset to be described (TCS) G159=1 to G159=9 and G54 to G59 Input without address "G159=" or "G" If not specified, then measurement only but no write function Only permitted when G53 is active at cycle call. |
@P9 | Shift the measuring point along the X axis |
@P10 | Shift the measuring point along the Y axis |
@P13 | Safety clearance for pre-positioning If @P13 is not specified, the entire measuring section is traversed at the measuring feed rate |
@P14 | Angle of hole circle [degrees] Default value = 360 |
@P15 | Angle between the drilled holes - Alternatively, this parameter can be made using @P30 |
@P16 | Starting angle [degrees] Default value = 0 |
@P30 | Number of drilled holes If not specified, the number of drilled holes is calculated from the angle values. |
@P33 | Crossover range (unsigned) [mm, inch]Default value = 5 |
The number of drilled holes can be defined by the angle between the drilled holes or the number of drilled holes. It is not permissible to specify @P15 and @P30 in the same cycle.
It is recommended to use the Syntax check.to verify whether the input parameters are correctly assigned.