Process (internal cycle)
- Measurements in Z direction
- After the start of the cycle, position the touch probe manually above the 1st measuring point.
- Press Start again to start the measurement run.
- Repeat this process with point 2 and point 3.
- Then lift to the security distance @P13.
- The orientation of the top surface is calculated and axes A, B and C are swivelled in.
- Measurements in X direction
- Then approach starting point 4 and press Start again.
- Afterwards, approach starting point 5 and press Start again.
- The measurement direction is determined from these points and positions 4 and 5 are measured automatically.
- Measurements in Y direction
- Approach point 6 manually and press Start.
- Finally, approach point 7 manually and press Start.
- The measurement direction is determined from these points and positions 6 and 7 are measured automatically.
- A new file is written CS_BASE_[CS ID @P39].bcs
Attention
If the file already exists, it is deleted and a new file is written. No back-up is made!