Parameters

Required input parameters

Input parameters

Description

@P4

Measurement path in X axis

@P5

Measurement path in Y axis

@P6

Measurement path in Z axis

@P39

Select the required CS to be written.

Value range: 1-10

Optional input parameters

Input parameters

Description

@P9

Shift the measuring point along the X axis (default: 0)

@P10

Shift the measuring point along the Y axis (default: 0)

@P11

Shift the measuring point along the Z axis (default: 0)

@P14

Angle 1 - Basic setting of the A axis (default: 0)

@P15

Angle 2 - Basic setting of the B axis (default: 0)

@P16

Angle 3 - Basic setting of the C axis (default: 0)

The touch probe must be configured in addition to supplying the input parameters described here. For more information on this function, see the section Configuration file.

The (calibrated) parameters of the touch probe (radius, length and offset in X and Y directions) are specified via the tool parameters.

It is recommended to use the Syntax check.to verify whether the input parameters are correctly assigned.