Parameters

Required input parameters

Cycle parameters

Description

@P65

Type

0 = length measurement

1 = radius measurement

2 = length and radius measurement

@P66

Measurement offset in Z for lateral measurements [mm, inch]

Only positive values are permissible.

Optional input parameters

Cycle parameters

Description

@P13

Clearance for lateral measurements [mm, inch]

Default value = 1/2 * current tool diameter (V.G.WZ_AKT.R)

@P23

Precision measurement repetitions

Default value = 1

@P33

Crossover range during measurement process [mm, inch]

Default value = 1/2 * current tool diameter (V.G.WZ_AKT.R)

@P37

Permissible tolerance of measuring point scatter.

Default value = 1/100 * (1/2 * current tool diameter) (1/100* V.G.WZ_AKT.R)

If the difference of the measured values exceeds this tolerance, an error is output.

@P64

Mode

0 = push (default value)

1 = pull

@P67

Lateral offset for length measurements [mm, inch]

Only positive values are permissible.

The value should stand at 0 for pointed tools, small tools and spherical tools.

Default value = 0

It is recommended to use the Syntax check.to verify whether the input parameters are correctly assigned.