Parameters

The following parameters are required to call the cycle:

Cycle parameters

Description

@P6

Measurement distance in the direction of the negative Z axis, only positive values permitted [mm, inch]

@P22

Measurement offset in Z for lateral measurements [mm, inch]

The following parameters can be modified as an option:

Cycle parameters

Description

@P13 (optional)

Safety clearance for lateral measurements [mm, inch]

Default value = 1/4 of measuring plate diameter.

@P14 (optional)

Probe angle for first lateral measurement [degrees]

Default value = 0

@P15 (optional)

Incremental angle for lateral measurements [degrees]

Default value = 360 / number of samples (@P23)

@P20 (optional)

Measuring station numbering (Required to read out the configuration from SysCalibToolSettingProbe.nc)

Default value = 1

@P23 (optional)

Number of lateral samples

Default value = 1

@P25 (optional)

Measuring mode

1 = Measure only tool length

2 = Measure only tool radius (tool must be known)

3 = Measure tool length tool radius (default value)