Parameters

Required input parameters

Input parameters

Description

@P6

Measurement distance in the direction of the negative Z axis, only positive values permitted [mm, inch]

@P22

Measurement offset in Z for lateral measurements [mm, inch]

Optional input parameters

Input parameters

Description

@P13

Safety clearance for lateral measurements [mm, inch]

Default value = 1/4 of measuring plate diameter.

@P14

Probe angle for first lateral measurement [degrees]

Default value = 0

@P15

Incremental angle for lateral measurements [degrees]

Default value = 360 / number of samples (@P23)

@P16

Measuring feedrate for a slow measurement

If defined, the measurements are repeated at the specified feedrate.

@P17

Radial return clearance for the slow measurement [mm, inch]

Default value = 1

@P18

Axial return clearance for the slow measurement [mm, inch]

Default value = 1

@P20

Measuring station numbering (Required to read out the configuration from SysCalibToolSettingProbe.nc)

Default value = 1

@P23

Number of lateral samples

Default value = 1

@P25

Measuring mode

1 = Measure only tool length

2 = Measure only tool radius (tool must be known)

3 = Measure tool length tool radius (default value)

It is recommended using the Syntax check.to verify whether the input parameters have been correctly assigned.