Parameters
The following parameters are required to call the cycle:
Cycle parameters | Description |
@P6 | Measurement distance in the direction of the negative Z axis, only positive values permitted [mm, inch] |
@P22 | Measurement offset in Z for lateral measurements [mm, inch] |
The following parameters can be modified as an option:
Cycle parameters | Description |
@P13 (optional) | Safety clearance for lateral measurements [mm, inch] Default value = 1/4 of measuring plate diameter. |
@P14 (optional) | Probe angle for first lateral measurement [degrees] Default value = 0 |
@P15 (optional) | Incremental angle for lateral measurements [degrees] Default value = 360 / number of samples (@P23) |
@P20 (optional) | Measuring station numbering (Required to read out the configuration from SysCalibToolSettingProbe.nc) Default value = 1 |
@P23 (optional) | Number of lateral samples Default value = 1 |
@P25 (optional) | Measuring mode 1 = Measure only tool length 2 = Measure only tool radius (tool must be known) 3 = Measure tool length tool radius (default value) |