ID 70541
Drive ident for torque limitation during fixed stop movement not configured. | |||
Description | A drive object must be configured to limit torque for the Move to fixed stop function [FCT-M8]. The list of drive objects must contain an object with the name TORQUE_LIMIT (see P-AXIS-00719).
Example for SERVOS drive; antr.fixed_stop.drive_ident[0].id TORQUE_LIMIT antr.fixed_stop.drive_ident[0].wr_ident S_0_0092 | ||
Response | Class | 7 | Controlled halt of the axis, the control loop is closed. Transition to error state. |
Solution | Class | 6 | Check and correct the parameterisation of the drive objects for Moving to fixed stop. Add the object for torque limitation. |
Parameter | %1 | Logical axis number [-] | |
Logical axis number P-AXIS-00016 of concerned axis. | |||
Error type | 11, Error message from position controller. | ||
|