ID 70549

Moving to fixed stop aborted by CNC reset.

Description

This error message is output for safety reasons if Move to fixed stop [FCT-M8] is aborted by a CNC reset and the fixed stop was not yet detected. Before the machine can continue, make sure that the obstacle or the fixed stop is removed from the motion path. This message can be suppressed by the axis parameter P-AXIS-00715 Remove obstacle or fixed stop.

Response

Class

6

Controlled halt of the axis, the control loop is closed. Transition to error state. Move to fixed stop is aborted

Solution

Class

7

Remove obstacle or fixed stop

Parameter

%1

Logical axis number [-]

Logical axis number P-AXIS-00016 of concerned axis.

%2

Current value [-]

Fixed stop detected

Error type

11, Error message from position controller.