ID 70550

Moving to fixed stop still active, fixed stop was detected.

Description

This warning message is generated if the CNC triggers a reset after the fixed stop is detected. The Move to fixed stop function remains active [FCT-M8]. The function must be terminated explicitly after the fixed stop is detected since a backward motion from the fixed stop should take place after deactivation. This warning message can be suppressed by the parameter P-AXIS-00717.

 

Example:

N10 G01 X0 F1000 X[FIXED_STOP OFF]

Response

Class

1

Warning, no reaction.

Solution

Class

1

Deactivate Move to fixed stop

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of concerned axis.

%2:

Current value [-]

State of the Move to fixed stop function.

%3:

Current value [-]

State of the fixed stop detection function.

%4:

Current value [0.1 10^-3 mm or ø]

Position of the fixed stop.

Error type

11, Error message from position controller.