Output of velocity feedforward control value (P-AXIS-00566)
P-AXIS-00566 | Output of velocity feedforward control value without IPO-LR delay | |
Description | When feedforward control is used, a delay of 5 interpolator cycles occurs between the path interpolator and the position controller. If this delay is not required and only velocity feedforward control is to be used, this parameter can force the immediate output of the position command value and the velocity feedforward control value to the position controller. | |
Parameter | vorsteuer.feedforward_without_delay | |
Data type | BOOLEAN | |
Data range | 0/1 | |
Axis types | T, R, S | |
Dimension | T: ---- | R,S: ---- |
Default value | 0 | |
Drive types | ---- | |
Remarks | If this parameter is set and a different feedforward control type is activated (acceleration or jerk feedforward control) in the parameter P-AXIS-00223 , the error message P-ERR-110624 is output and P-AXIS-00223 is corrected. |