ID 90191

TRC selection with mode G237 and active TGC not allowed.

Description

When the TRC is active, it is not possible to select the TRC with the G237 mode.

Response

Class

2

Abort NC program processing.

Solution

Class

3

Check and modify NC program. Use a different TRC selection mode

Error type

1, Error message from NC program.