ID 21987
Feed factor is out of permissible value range. | ||||
Description | An external path feed can be commanded via the PLC. In the NC program, this can be additionally weighted by a feed factor with #FF in [%] . The programmed feed factor here exceeds the permissible value range. | |||
Response | Class | 2 | Abort NC program processing. | |
Solution | Class | 7 | Check and modify NC program. Program a feed factor within the permissible data range. | |
Parameter | %1: | Error value [%] | ||
| ||||
%2: | Lower limit value [%] | |||
| ||||
%3 | Upper limit value [%] | |||
| ||||
%4 |
| |||
| ||||
%5 |
| |||
| ||||
Error type | 1, Error message from NC program. | |||
|