ID 110636

Activation/deactivation of single axis function in the path interpolator requires restart of the control.

Description

The single axis function in the path interpolator can only be activated and deactivated by the axis parameter P-AXIS-00457 by rebooting the controller. The previous setting remains active.

Response

Class

1

Warning and correction of parameter.

Solution

Class

1

Change the entry P-AXIS-00457 only in configuration mode or when the CNC is disabled.

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of axis affected.

%2:

Current value [-]

Commanded value of P-AXIS-00457

%3:

Corrected value

[-]

Corrected value of P-AXIS-00457

Error type

2, Error message by data transfer from parameter list into control device.