Parametrisation
Required input parameters
Input parameters | Description |
@P49 | Retraction plane (absolute) |
@P1 | Reference plane (absolute) |
@P13 | Safety clearance (relative to the reference plane, unsigned) |
@P45 | Final drilling depth (relative to the reference plane, unsigned) |
Optional input parameters
Input parameters | Description |
@P47 (optional) | Dwell time at final drilling depth (in seconds) |
@P80 (optional) | Retraction mode (default value = 1) 0: Retract at rapid traverse 1: Retract at feedrate |