Incomplete or illegal vector of rotation axis when defining the inclination of probe. | |||
Description | A definition of the inclination by a rotation axis is required with the parameters @P94, @P95 and @P96 to adapt the measurement movements to an inclined robe at the beginning of the cycle. The rotation axis is defined as a vector, where @P94 is defined as the X component, @P95 the Y component and @P96 the Z component. The vector must have a length greater than zero. | ||
Response | Class | 2 | Error: Transition to error state. Complete reset of the NC channel necessary. |
Solution | Class | 3 | Complete definition of the inclination of the probe by a rotation axis with the parameters @P94, @P95 and @P96. |
Error type | 1, Error message from NC program. | ||
|