ID 14307

Y coordinate must be smaller at starting point than at target point.

Description

In the face milling cycle in the plane G18, the Y coordinate of the starting point must be smaller than the Y coordinate of the target point. This is not the case.

Response

Class

-

Error: Transition to error state. Complete reset of the NC channel necessary.

Solution

Class

-

Correct the Y coordinate of the starting point.

Error type

1, Error message from the NC program