Filter - frequency (P-AXIS-00739)

P-AXIS-00739

Frequency range of the additional interface filter

Description

The parameter defines the frequency range for:

  • Low-pass: Beginning of cut-off frequency range (ideal filter)
  • High-pass: Beginning of cut-off frequency range (ideal filter)
  • Band-pass and band-stop filters: middle frequency

Parameter

lr_param.add_interface.filter[i].fg_f0

Data type

REAL64

Data range

0 < FG_F= > 0.5/Tfall (where Tfall is the NC cycle time)

Axis types

T, R, S

Dimension

T: Hz

R,S: Hz

Default value

30

Drive types

----

Remarks