Filter – order (P-AXIS-00736)
P-AXIS-00736 | Order of the additional interface filter | |
Description | This parameter defines the filter order. In addition, this parameter is a value which expresses the fall of frequency response (fall = -order x 20 dB/decade). The value order = 0 means: no filter connected. | |
Parameter | lr_param.add_interface.filter[i].order | |
Data type | UNS32 | |
Data range | 0 < order < 6 for low-pass, high-pass and all-pass filters 0 < order < 3 for band-pass and band-stop filters order = 0 or <= 1 for PT1 filters order = 0 or <= 1 for PT2 filters | |
Axis types | T, R, S | |
Dimension | T:---- | R,S: ---- |
Default value | 2 | |
Drive types | ---- | |
Remarks | An order of < 1 need only be specified for filters types PT1, PT2 and TIME_DELAY to activate the filter. The corresponding order is calculated internally. |