ID 22060

#FILTER and #VIB GUARD cannot be combined.

Description

The NC program was programmed with the NC commands for the Vibration Guard function (#VIB GUARD) and with the NC commands for the FIR filter function (#FILTER). This is not allowed. It is not permitted to combine Vibration Guard and Filter functions.

Response

Class

2

Abort NC program processing.

Solution

Class

3

It is only allowed to program either Virbation Guard or filter functions.

Error type

1, Error message from NC program.