ID 14324
Safety distance in Z is not or incorrectly defined. | |||
Description | No or incorrect definition of the safety distance in the Z plane. The value of the reference plane added to the safety distance may not be greater than the value of the retraction plane. | ||
Response | Class | - | Error: Transition to error state. Complete reset of the NC channel necessary. |
Solution | Class | - | Define the safety distance in the Z plane at the cycle call with a value greater than zero. |
Error type | 1, Error message from NC program. | ||
|