ID 14324

Safety clearance in Z is not or incorrectly defined.

Description

No or incorrect definition of the safety clearance in the Z plane. The value of the reference plane added to the safety clearance may not be greater than the value of the retraction plane

Response

Class

-

Error: Transition to error state. Complete reset of the NC channel necessary.

Solution

Class

-

Define the safety clearance in the Z plane at the cycle call with a value greater than zero.

Error type

1, Error message from the NC program