ID110629

Permanent activation of HSC filters not possible.

Description

On checking the filter parameters, it was detected that an attempt was made in an axis to activate an HSC filter via

filter[0].enable 1

permanently.

Permanent activation of HSC filters is not possible, only of FIR filters.

Response

Class

1

Parameter for permanent activation is reset and the start-up is continued.

Solution

Class

1

Check and modify the parameters.
Permanent activation can only be used for FIT filters.

Parameter

%1:

Logical axis number [-]

Logical axis number of the axis where the invalid parameter was configured.

%2:

Error value[-]

Value set for permanent activation for P-AXIS-00573.

%3

Error value[-]

Filter prototype (P-AXIS-00153) which was configured for this axis.

Error type

2, Error message by data transfer from parameter list into control device.