ID110632

Invalid value for filter share factor.

Description

The filter share factor (P-AXIS-00590) was configured with an invalid value.

The value value range is from 0 to 100%.

With a configured value less than 0, the value is corrected to 0 so that the filter is deactivated.

Response

Class

1

The filter share factor P-AXIS-00590 is corrected and the start-up is continued.

Solution

Class

1

Check and modify the parameters.
Use a valid value for the filter share factor P-AXIS-00590

Parameter

%1:

Logical axis number [-]

Logical axis number of the axis where the invalid combination was configured.

%2:

Error value[%]

Incorrectly parameterised filter share factor P-AXIS-00590

%3

Corrected value [%]

Corrected filter share factor

Error type

2, Error message by data transfer from parameter list into control device.