ID110633
Invalid frequency value. | ||||
Description | On checking the filter parameters, it was detected that an invalid value was specified in an axis for the limit frequency of the FIR filter (P-AXIS-00585) or the machine natural frequency (P-AXIS-00589). | |||
Response | Class | 1 | The corresponding parameter is set to the default value and the start-up is continued. | |
Solution | Class | 1 | Check and modify the parameters (P-AXIS-00585) and (P-AXIS-00589). | |
Parameter | %1: | Logical axis number [-] | ||
Logical axis number of the axis where the invalid combination was configured. | ||||
%2: | Error value[Hz] | |||
Incorrect frequency specified. | ||||
%3 | Corrected value[Hz] | |||
Corrected frequency value | ||||
Error type | 2, Error message by data transfer from parameter list into control device. | |||
|