Parameters
The touch probe must be configured in addition to supplying the input parameters described here. For more information on this function, see the section Configuration file.
The (calibrated) parameters of the touch probe (radius, length and offset in X and Y directions) are specified via the tool parameters.
Required input parameters
Input parameters | Description |
@P2 | Estimated spigot diameter. Here, an approximate parameter is sufficient. For calculating pre-positioning. |
Optional input parameters
Input parameters | Description |
@P7 | Zero offset to be described (TCS) G159=1 to G159=9 and G54 to G59 Input without address "G159=" or "G" If not specified, then measurement only but no write function Only permitted when G53 is active at cycle call. |
@P9 | Shift the measurement result along the X axis |
@P10 | Shift the measurement result along the Y axis |
@P13 | Safety clearance for pre-positioning Default: diameter of touch probe |
@P14 | Angle to measuring point 1 in relation to X+ axis [degrees] Default: 0 |
@P15 | Incremental angle [degrees] Default: 120 |
@P19 | Pre-positioning in the Z axis, relative |
@P33 | Crossover range (unsigned) [mm, inch] Default: 5 |
It is recommended to use the Syntax check.to verify whether the input parameters are correctly assigned.