Parameters

The touch probe must be configured in addition to supplying the input parameters described here. For more information on this function, see the section Configuration file.

The (calibrated) parameters of the touch probe (radius, length and offset in X and Y directions) are specified via the tool parameters.

Required input parameters

Input parameters

Description

@P2

Estimated spigot diameter. Here, an approximate parameter is sufficient. For calculating pre-positioning.

Optional input parameters

Input parameters

Description

@P7

Zero offset to be described (TCS)

G159=1 to G159=9 and G54 to G59

Input without address "G159=" or "G"

If not specified, then measurement only but no write function

Only permitted when G53 is active at cycle call.

@P9

Shift the measurement result along the X axis

@P10

Shift the measurement result along the Y axis

@P13

Safety clearance for pre-positioning

Default: diameter of touch probe

@P14

Angle to measuring point 1 in relation to X+ axis [degrees]

Default: 0

@P15

Incremental angle [degrees]

Default: 120

@P19

Pre-positioning in the Z axis, relative

@P33

Crossover range (unsigned) [mm, inch]

Default: 5

It is recommended to use the Syntax check.to verify whether the input parameters are correctly assigned.