Activating the Vibration Guard (P-AXIS-00588)

P-AXIS-00588

Activating the Vibration Guard

Description

This parameter can permanently activate or deactivate the Vibration Guard function at program start.

Parameter

vib_guard.active

Data type

BOOLEAN

Data range

0/1

Axis types

T, R, S

Dimension

T: ----

R,S: ----

Default value

0

Drive types

----

Remarks

Alternatively, the Vibration Guard can also be activated or deactivated by the NC command #VIB GUARD / OFF .

The parameter is available as of V3.1.3075.00