Damping factor of natural frequency (P-AXIS-00568)

P-AXIS-00568

Damping factor of natural frequency

Description

Besides the natural frequency itself, this parameter can also specify the damping factor of the natural frequency which is defined as follows:

Parameter

vib_guard.damping

Data type

REAL64

Data range

0 ≤ damping ≤ 1

Axis types

T, R, S

Dimension

T: ----

R,S: ----

Default value

0.1

Drive types

----

Remarks

The parameter is available as of V3.1.3075.00