Overview

Start-up parameters

ID

Parameter

Description

P-STUP-00166

no_error_message_at_reset

Logging a CNC reset

P-STUP-00167

error_protocol_mode

Logging mode

P-STUP-00168

error_text_of_id

Name of the file for error message texts

P-STUP-00169

error_text_user_of_id

Name of the file for user-specific error message texts

P-STUP-00170

error_log_file_name

Name of the error log file

P-STUP-00171

error_log_file_max_size

Maximum size of the error log file

P-STUP-00172

error_plc_wait_cycles

Waiting cycles before evaluation of PLC activation

P-STUP-00173

error_ao_name

Additional descriptive text (AO name)

P-STUP-00186

error_filter[i].reason

Identification of the error (cause)

P-STUP-00187

error_filter[i].action

Error action to be performed

P-STUP-00188

error_filter[i].conditional_activation

Activation via PLC/HMI

P-STUP-00189

error_filter[i].conditional_action

Action that is only activated after enabling by PLC/HMI

P-STUP-00190

error_filter[i].conditional_param

Additional comparison parameter in the event of a drive error message

P-STUP-00191

error_filter[i].conditional_output

Individual additional error information for output

P-STUP-00200

error_text_cycles_of_id

Name of the file for error message texts of CNC cycles

Channel parameters

ID

Parameter

Description

P-CHAN-00338

mdi_log_file

Name of the manual block log file

P-CHAN-00339

mdi_log_file_max_size

Maximum size of the manual block log file

P-CHAN-00378

error_filter[i].reason

Identification of the error (cause)

P-CHAN-00379

error_filter[i].action

Error action to be performed

P-CHAN-00380

error_filter[i].conditional_activation

Activation via PLC/HMI

P-CHAN-00381

error_filter[i].conditional_action

Action that is only activated after enabling by PLC/HMI

P-CHAN-00382

error_filter[i].conditional_param

Additional comparison parameter in the event of a drive error message

P-CHAN-00383

error_filter[i].conditional_output

Individual additional error information for output

Axis parameter

ID

Parameter

Description

P-AXIS-00627

error_filter[i].reason

Identification of the error (cause)

P-AXIS-00628

error_filter[i].action

Error action to be performed

P-AXIS-00629

error_filter[i].conditional_activation

Activation via PLC/HMI

P-AXIS-00630

error_filter[i].conditional_action

Action that is only activated after enabling by PLC/HMI

P-AXIS-00631

error_filter[i].conditional_param

Additional comparison parameter in the event of a drive error message

P-AXIS-00632

error_filter[i].conditional_output

Individual additional error information for output