ID 22088
Axis index of programmed axis is out of range of permissible values.. | ||||
Description | Too many member kinematics are configured for a couple kinematic. The number of member kinematics results from the sum of member kinematics per group. | |||
Response | Class | 2 | Abort NC program processing. | |
Solution | Class | 3 | Check and modify NC program. Check whether the axis index is within the defined limits in the programmed axis identifiers or logical axis numbers. | |
Parameter | %1: | Error value [-] | ||
Invalid axis index | ||||
%2: | Current value [-] | |||
Related logical axis number | ||||
%3: | Current value [-] | |||
Related axis identifier | ||||
%4: | Lower limit value [-] | |||
Minimum axis index | ||||
%5: | Upper limit value [-] | |||
Maximum axis index | ||||
Error type | 1, Error message from NC program. | |||
|