Maximum number of table entries for leadscrew error compensation (P-COMP-00059)

P-COMP-00059

Maximum number of table entries for leadscrew error compensation

Description

This leadscrew error compensation parameter (FCT-C5) sets the memory space required for a particular number of table entries.

 

The size of the actually used compensation table is defined by `kw_nr_max` (P-COMP-00020) and `kw_nr_max` must be smaller than `max_points`.

Parameter

kw.ssfk.max_points

Data type

UNS32

Data range

0 <= P-COMP-00059

Axis types

T, R, S

Dimension

T: ----

R,S: ----

Default value

1500

Remarks

The parameter value can no longer be changed after start-up or after lists are reloaded. Otherwise error ID 110638 is output.

 

If P-COMP-00059 is not specified (or assigned the value 0), the default value is assigned to P-COMP-00059 for downward compatibility reasons. 

To avoid the default assignment, memory can be saved for an axis that does not use leadscrew error compensation by assigning the value 1 to P-COMP-00059.