Error reaction for missing drive releases (P-AXIS-00763)
P-AXIS-00763 | Error reaction for missing drive releases. | |
Description | If the drive releases are reset after the fixed stop is detected, the CNC generates the error message P-ERR-70546 and aborts the function "Move to fixed stop". This behaviour can be changed by the parameter "error_missing_drive_releases". | |
Parameter | antr.fixed_stop.error_missing_drive_releases | |
Data type | STRING | |
Data range | ERROR: Output of error message P-ERR-70546 and the Move to fixed stop function is aborted WARNING: Output of warning P-ERR-70546 and the Move to fixed stop function is aborted NONE: Abort the Move to fixed stop function | |
Axis types | T, R | |
Dimension | T: ---- | R: ---- |
Default value | ERROR | |
Drive types | SERCOS, CANopen | |
Remarks | Check the motion range of the axis before you set each release again. The stop obstacle must be removed. |