restart
P-STUP-00213 | Number of logging entries for logging |
Description | This parameter sets the maximum number of log entries for the corresponding task. Real-time events are logged in these entries for diagnostic purposes. After the number is reached, logging stops automatically. With a value=0, no log file is generated at CNC start-up. |
Parameter | trace.geo.max_records |
Data type | SGN32 |
Data range | 0 <= max_records < MAX_UNS32 |
Dimension | ---- |
Default value | 0 |
Remarks |
|
P-STUP-00214 | Name of the output file |
Description | This parameter is used to specify the name of the output file for logging the corresponding task. If no path is specified for the output file, the default path or the main directory of the NC controller is used. |
Parameter | task_trace.geo.filename |
Data type | STRING |
Data range | <Filename with relative / absolute path> |
Dimension | ---- |
Default value | <TwinCATInstallation>\Components\Mc\Cnc\Diagnostics\MultiCore-Startup.log |
Remarks |
|
P-STUP-00215 | Name of the history file |
Description | This parameter is used to specify the name of the history file for logging the corresponding task. The file is used to output the history logs. If no path is specified for the file, the default path or the main directory of the NC controller is used. |
Parameter | task_trace.geo.history_filename |
Data type | STRING |
Data range | <Filename with relative / absolute path> |
Dimension | ---- |
Default value | <TwinCATInstallation>\Components\Mc\Cnc\Diagnostics\MultiCore-History.log |
Remarks |
|