restart

P-STUP-00213

Number of logging entries for logging

Description

This parameter sets the maximum number of log entries for the corresponding task. Real-time events are logged in these entries for diagnostic purposes.

After the number is reached, logging stops automatically.

With a value=0, no log file is generated at CNC start-up.

Parameter

trace.geo.max_records

Data type

SGN32

Data range

0 <= max_records < MAX_UNS32

Dimension

----

Default value

0

Remarks

 

P-STUP-00214

Name of the output file

Description

This parameter is used to specify the name of the output file for logging the corresponding task.

If no path is specified for the output file, the default path or the main directory of the NC controller is used.

Parameter

task_trace.geo.filename

Data type

STRING

Data range

<Filename with relative / absolute path>

Dimension

----

Default value

<TwinCATInstallation>\Components\Mc\Cnc\Diagnostics\MultiCore-Startup.log

Remarks

 

P-STUP-00215

Name of the history file

Description

This parameter is used to specify the name of the history file for logging the corresponding task. The file is used to output the history logs.

If no path is specified for the file, the default path or the main directory of the NC controller is used.

Parameter

task_trace.geo.history_filename

Data type

STRING

Data range

<Filename with relative / absolute path>

Dimension

----

Default value

<TwinCATInstallation>\Components\Mc\Cnc\Diagnostics\MultiCore-History.log

Remarks