ID 70614

Actual axis position is in the invalid SWE interval with positive axis velocity.

Description

The current position of the modulo axis with a positive velocity has reached an invalid range defined by the software limit switches.

This error only occurs if a software limit switch is shifted to a value outside the modulo range by the specified tolerance.

Possible causes:

  • Incorrect NC program
  • Overshoots of axis are too wide.

 

For further information see [FCT-A2// Description]

Response

Class

7

Controlled halt of the axis, the control loop is closed.

Solution

Class

6

Possible solutions:

  • Check and correct the NC program
  • Check the gain factor (P-AXIS-00099) to reduce axis overshoots
  • Check and increase the tolerance P-AXIS-00179

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of concerned axis

%2:

Current value [0.1 10^-3 mm or ø]

Current position of the axis

%3:

Lower limit value [0.1 10^-3 mm or ø]

Lower limit of the invalid modulo range defined by the software limit switches

%4:

Current value [0.1 10^-3 mm or ø]

Configured tolerance P-AXIS-00179 of the software limit switch

%5:

Block number [-]

Block number of the NC program in which the error occurred.

Error type

-