Position lag limit for fixed stop detection when measuring travel on fixed stop (P-AXIS-00774)
P-AXIS-00774 | Position lag limit for fixed stop detection when measuring travel on fixed stop | |
Description | This parameter defines the position lag that must be exceeded to detect a fixed stop when measuring on a fixed stop. When set to the value 0, the system check of the position lag to detect a fixed stop is deactivated. If this parameter has the value < 0 (default assignment), a check is made whether P-AXIS-00769 has the value > 0 and this is used if necessary. If P-AXIS-00769 is also < 0, the value of P-AXIS-00331 is used to detect the fixed stop. | |
Parameter | kenngr.measure.fixed_stop_detect.pos_lag_limit | |
Data type | SGN32 | |
Data range | MIN(SGN32) < P-AXIS-00774 < MAX(SGN32) | |
Axis types | <T, R> | |
Dimension | T: 0.1 µm | R: .1* 10- 4 ° |
Default value | -1 | |
Drive types | SERCOS, Terminal, Lightbus, Profidrive, CANopen* | |
Remarks | *Delete axis types that do not apply! Parameter available as of CNC Build V2.11.2810.01 and higher |