Minimum time for fixed stop detection when measuring travel on fixed stop (P-AXIS-00775)
P-AXIS-00775 | Minimum time for fixed stop detection when measuring travel to fixed stop | |
Description | This parameter defines the length of time that the test conditions for detection of the fixed stop must be fulfilled when measuring to fixed stop so that the fixed stop is considered to be detected. If this parameter has the value zero (default), the system checks whether P-AXIS-00770 has a value > 0 and, if so, this is used. If P-AXIS-00770 is also 0, the value of P-AXIS-00332 is used as the time limit for fixed stop detection. | |
Parameter | kenngr.measure.fixed_stop_detect.min_time | |
Data type | UNS32 | |
Data range | 0 < P-AXIS-00775 < MAX(UNS32) | |
Axis types | <T, R> | |
Dimension | T: µs | R: µs |
Default value | 0 | |
Drive types | ---- | |
Remarks | Parameter available as of CNC Build V2.11.2810.01 and higher |