ID 14337

The identification number of the main contour was not defined or is incorrect.

Description

No main contour identification number or an incorrect one was transferred. With pocket milling, the main contour describes the pocket contour; with spigot milling, it describes the blank contour; and with path milling it describes the path contour.

Response

Class

-

Error: Transition to error state. Complete reset of the NC channel necessary.

Solution

Class

-

Transfer a positive and integer identification number of the main contour with a value greater than zero.

Error type

1, Error message from NC program.