ID 14343

The transferred radius for the contour milling is not defined or is defined incorrectly.

Description

The transferred radius of contour milling is not or incorrectly defined. It must be greater than zero.

Response

Class

-

Error: Transition to error state. Complete reset of the NC channel necessary.

Solution

Class

-

Transfer a contour milling radius that is greater than zero.

Parameter

%1:

Error value

Affected input parameter @P__.

Error type

1, Error message from the NC program