ID 292070

CNC interface version is too old. Incompatible with current TcCOM object of external compensation.

Description

The interface version of the CNC is compared with that of the TcCOM object of the external compensation. The system detected that the interface version of the CNC is too old.

Response

Class

7

Controlled halt of the axis, the control loop is closed.

Solution

Class

6

Update the CNC to obtain the compatibility of the interface.

Parameter

%1:

Current value [-]

Error number

%2:

Current value [-]

Major version number of the TcCOM object interface

%3:

Current value [-]

Minor version number of the TcCOM object interface

%4:

Error value [-]

Major version number of the CNC interface.

%5:

Error value [-]

Minor version number of the CNC interface.

Error type

11, Error message from position controller.